Enter the command to change the status of relay 2. The relay will be in the
position as before restart after the terminal restart.
at^screl2=1
Enter the command to change the status of relay 2.
at^screl2=1,0
Enter the command to change the status of relay 2. The relay will be in the
opposite position after restart.
at^screl2=1,1
Enter the command to change the status of relay 2. The relay will be in this
position after restart.
at^screl2=1,2
Enter the command to change the status of relay 2. The relay will be in the
position as before restart after the terminal restart.
ADC – Input Circuits
These commands help control the input circuits, set calibration and make
measurements.
at^scadc1="get_value"
Enter the command to measure the value of the selected port and send the
measured value.
at^scadc1="adc_value"
Enter the command to make the measurement and return the A/D converter
value.
at^scadc1="calib_min"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scadc1="calib_max"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scadc1="threshold_low",200
Manual calibration setting (minimum values). Setting options: 0 – 960.
at^scadc1="threshold_high",250